Leica LS15 Digital Level with Autofocus

Automated functions and industry-leading 0.2 mm accuracy to standard Invar staffs deliver unmatched reliability. Precision begins by using the electronic level bubble to set up instruments. After one button press, automatic tilt checks are made prior to each measurement. Integrated auto-focus not only finds your target faster, it increases measurement accuracy by maximising contrast of the staff.

Users profit from Leica Geosystems experience as inventors and industry leaders of digital levels. Honing the digital level into an art form, these solutions collect results faster with the highest accuracy available.

Standard Kitcontains;2 GEB331, Battery int Li-Ion ,1 GKL311 single Chargerset,1 MS1 USB 1GB,1 SPF04 Screen protection
Kit Option 1 Kit Option 2
2 GEB331, Battery int Li-Ion
1 GKL311 single Chargerset
1 MS1, USB memory stick, 1GB
1 SPF04 Screen protection
1 Wooden Tripods
1 GTL4M Telescopic staff, 4m, fibreglass
2 GEB331, Battery int Li-Ion
1 GKL311 single Chargerset
1 MS1, USB memory stick, 1GB
1 SPF04 Screen protection
1 Wooden Tripods
1 GPCL2, Invar Staff with Bar Code

 

SPECIFICATIONS
Height Measurement Accuracy(1) using standard Invar staff |0.3 mm
Accuracy(2) using standard staff |1.0 mm
Distance Measurement Accuracy(3) |15 mm at 30 m
Measurement Range Minimum range |1.8 m
Maximum range(4) |110 m
Auto-Focus Working range |1.8 m to infinity
Time to focus |Typically 4 sec
Overview Camera

Field of view |6 x 4.8 (7.7 diagonal)
Frame rate |Up to 20 frames per second

Digital Compass Accuracy |2.7
Data Storage 30,000 measurements
Minimum focusing distance |0.6 m
Environmental Specifications  Working temperature range |-20 C to +50 C
Dust / Water (IEC 60529) |IP55
Dust/Waterproof IP57 gas filled
(1) - Standard deviation, 1 km double run, ISO 17123-2. GPCL3  standard Invar staff or equivalent
(2) - Standard deviation, 1 km double run, ISO 17123-2. GKNL4M standard staff or equivalent.
(3) - Standard deviation, 500 ppm for up to 50 m, 1000 ppm for distances beyond 50 m.
(4) - For standard staffs exceeding 3 m length, 60 m for Invar staffs

 